When the Heat is On
As the temperature increases, so too does the demand for electricity. Increased use of air conditioners and indoor electronics taxes most electricity providers’ supplies. In order to compensate, energy companies please with consumers to conserve energy and reduce usage.
APC provides a quick, easy online quiz to help determine your susceptibility to power problems. The results will help determine whether you are considered average, above average or even high risk. Go to www.apc.com/tools/risk/index.cfm.
In a Flash
According to the Electrical System Reliability Task Force (an advisory board to the U.S. Secretary of Energy), hot weather-induced line sags and flashovers from transmission lines to trees can also cause outages. Tree limbs near overhead lines cause outages when they come in contact with conductors, thereby short-circuiting the lines. *Such short circuits can also cause surge-related damage to unprotected home electronics). In addition to heat caused outages, summer usually means an increase in thunderstorm and lightning activity.
|
|
APC BACK-UPS ES 8 OUTLET 350VA 120V
(BE350R)
$56.00 |
The Back-UPS ES offers affordable battery backup and surge protection for home computers. With enough power outlets to protect your entire system, built-in phone/fax/modem line (DSL compatible) protection and easy-to-install safe system shutdown software, all make this power protection solution the best value for home and home office computers.
| Battery Enclosure Type |
Internal |
| Depth |
3.4 in |
| Device Type |
UPS |
| Form Factor |
External |
| Height |
7.1 in |
| Weight |
8.8 lbs |
| Width |
10.9 in |
| Technology |
Lead acid |
| Humidity Range Operating |
0 - 95% |
| Max Operating Temperature |
104 F |
| Min Operating Temperature |
32 F |
| Compliant Standards |
FCC Class B certified, cUL, NOM, UL 1778, FCC Part 68, FCC Part 15, CSA C22.2 |
| Circuit Protection |
Circuit breaker |
| Energy Rating |
375 Joules |
| Frequency Required |
50/60 Hz |
| Input Voltage |
AC 120 V |
| Input Voltage Range |
AC 88 - 139 V |
| Output Voltage |
AC 115 V 8% ( 50/60 Hz ) |
| Output Waveform |
Stepped approximation to a sinewave |
| Output connector(s) |
8 |
| Power Provided |
350 VA |
| UPS Technology |
Off-lin | |
|
APC BACK-UPS ES 8 Outlet 650VA 120V
(BE650R)
$105.00 |
Back-UPS ES, 650VA/390W, Input 120V/Output 120V. The Back-UPS ES offers affordable battery backup and surge protection for home computers. With enough power outlets to protect your entire system, built-in phone/fax/modem line (DSL compatible) protection and easy-to-install safe system shutdown software all make this power protection solution the best value for home and home office computers. I
Includes UPS, CD with software, Free Trial Software, USB cable, User Manual, Wall-mounting template.
PROTECTION - Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment. - Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. - Dataline Surge Protection Provides protection of connected equipment from power surges on the data lines. - Lifetime data recovery warranty Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit. - Safety-agency approved Ensures product testing and approval to work safely with the connected loads and within the environment. CONVENIENCE - Audible alarms Provides notification of changing utility power and UPS conditions. - Automatic self-test Ensures early detection of potential problems by periodic testing of UPS components. - Cold-start capable Provides temporary battery power when the utility power is out. - Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment throughout battery replacement. - Resettable circuit breakers Enables quick recovery from UPS overload events. - Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles. MANAGEABILITY - USB connectivity Provides management of the UPS via USB port. SPECIFICATIONS OUTPUT - Power Capacity : 650 VA 390 watts Nominal Voltage: 120V Waveform Type : Stepped approximation to a sinewave Connections : (4) NEMA 5-15R (battery backup) (4) NEMA 5-15R (surge protection) INPUT - Nominal Voltage: 120 V Frequency : 50/60 Hz Connection : NEMA 5-15P with 6 ft. cord Voltage Range : 88 ~ 139 V BATTERIES & RUNTIME- Battery Type : Maintenance-free sealed Lead-Acid battery withsuspended electrolyte, leakproof. Replacement battery is RBC17 Recharge Time : 16 hours (typical) Backup Time : 15.4 minutes (195 watts) at half-load; 4.2 minutes (390 watts) at full-load COMMUNICATIONS & MANAGEMENT- Control panel : LED status display with On Line, On Battery, Replace Battery and Building Wiring Fault. Audible alarm : Alarm when on battery, distinctive low battery alarm, overload continuous tone alarm. SURGE PROTECTION & FILTERING- Surge rating : 365 Joules Filtering : Full time multi-pole noise filtering, 5% IEEE surge let-through, zero clamping response time, meets UL 1449. Dataline protection: RJ-11 Modem/Fax/DSL/10/100BaseT protection, Coaxial Video/Cable protection.
APPROVALS - cUL Listed, FCC Part 15 Class B, FCC Part 68, NOM, UL 1778, UL 497A, UL 498.
DIMENSIONS- 11.14"w x 3.78"h x 7.09"d WT. - 15.62 lbs. |
|
APC Notebook SurgeArrest
(PNOTEPROC6-3pin)
(PNOTEPROC8-2pin)
$25.99 |
FEATURES
SurgeArrest NotebookPRO C8 W/TEL/NET 100-240V Reliable power protection for Notebook computers, fax and answering machines. Protecting just the AC line for a notebook computer is not enough. Lightning or other damaging surges can enter and destroy your equipment through the phone line as well. The SurgeArrest Notebook Protector protects both paths - and guarantees it! Includes Surge Unit, 1.8 Meter Tel Cable (2), 30 cm Network Patch Cable, Cord Management Straps, User Manual. * IEEE let-through rating and UL 1449 compliance IEEE tests simulate a surge of 6,000 volts, such as in a direct lightning hit. Let through rating indicates the maximum voltage that will reach your equipment when suppressed by an APC Surge Protector. Typical equipment, such as computers and home electronics, are built to withstand surges up to 500 volts, thus 330V let through volts would not put any stress on your equipment. APC Surge Protector's let through rating exceeds ULs toughest standard (UL 1449) of let through rating of less than 330 volts. * Data-line Protection Reliable power protection for Notebook computers and data line protection for a modem, fax, phone or answering machine. * Noise Filtering SurgeArrest attenuates EMI/RFI line noise that can cause data errors and keyboard lockups, ensuring better performance of protected equipment. * Cord Management To help organize power cords. * Fail Safe Mode Most other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APCs Surge Protectors fail safe, which means that once the circuit of an APC Surge Protector has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment. * Protection working indicator SurgeArrest will warn you if its circuitry has been damaged by heavy strike or power line surge and it is unable to provide 100% protection. If still under warranty, APC will then replace your damaged SurgeArrest free of charge. SPECIFICATIONS OUTPUT SPECs- Outlets : (1) IEC 320-C8 INPUT SPECs - Nominal voltage : 120 Volts Frequency : 50/60 Hz Connection Type : IEC 320 C8 Max. Line Current : 4 Amp per phase SURGE PROTECTION & FILTERING- Surge energy rating: 180 Joules Peak Current : 6.50 kAmps (normal mode) NM Surge Response Time : 1 ns Dataline Protection: RJ-11 Modem/Fax protection (two wire single line). RJ45 10/100BaseT Ethernet protection Let Through Voltage Rating : < 330 APPROVALS - CSA, FCC Part 68, NOM, UL Listed SIZE - 1.26"w x 1.08"h x 3.86"d WT.- 0.20 lbs. |
|
APC ProtectNet Analog Telephone Connector
(PTEL2)
$24.99 |
ProtectNet Standalone Surge Protector for one Analog Telephone Line.The majority of all surge-induced damage is caused by surges and spikes traveling along unprotected data lines. These surges originate from a wide variety of sources, including static charge buildup and lightning strikes. Left unprotected, your data lines expose network cards, A/V components, modems and other network equipment to damaging electrical transients. The ProtectNet family of stand-alone surge suppressors protects individual data lines, including telephone and network lines, coax cables, and more. Inserting a ProtectNet in your data line and connecting it to earth ground prevents back-door surges from ruining your productivity and costing you money. * Data-line Protection Protection against powers spikes traveling through data lines ensures complete protection of your equipment from surges. It is very important to protect your equipment from "back door" surges traveling through data lines, as they can be as damaging to your equipment as surges traveling over power lines. * Fail Safe Mode Most other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's Surge Protectors fail safe, which means that once the circuit of an APC Surge Protector has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment. * Lightning and Surge Protection A protection plan incorporating data line and AC line surge suppression will "bullet-proof" your system against the hazards of surges caused by lightning faults and electro-static discharge SPECIFICATIONs
SURGE PROTECTION & FILTERING- Peak Current Normal Mode : 0.20 kAmps Peak Current Common Mode : 0.15 kAmps NM Surge Response Time : 1 ns Dataline protection : RJ-45 Modem/Fax/DSL protection (four wire dual line) Data Lines Protected : (multi-line only) 3-6 RJ45 Let Through Voltage Rating: < 260 APPROVALS - CSA , UL 497A , UL Listed SIZE - 1.87"w x 4.0"h x 1.10"d WT.- 0.14 lbs. | |
|